Dell R710 PCIE Fatal Err

E171F PCIE Fatal Err B0 D3 F0 is shown in orange on the front display panel as the server crashes.
to restart the monitor to the PCIE Fatal Err: Critical Event sensor, bus
Fatal error (bus 0 Device 3 Function 0) was asserted 】, cannot be started.
fault cause: two liquid capacitors on SAS 5i card are damaged. The top of the capacitor can be seen bulging in appearance.
solution: replace the capacitance, the capacitance is 1500uf, the voltage is 6.3v, the temperature resistance is 105℃.
you only need to remove the SAS 5i card and go to the local place where the computer can be repaired. You can spend from 10 yuan to
20 yuan and ask the computer repairman to remove the broken capacitor and replace it with a new one.
capacitance selection: the height of the capacitance shall be less than or equal to the original capacitance (too high, the chassis cover will not be able to be covered), the capacitance shall be
amount, the voltage must be consistent, the temperature resistance shall be approximately equal to the original temperature resistance.
sanyo’s solid capacitance is the best choice, followed by sanyo’s liquid capacitance.
SAS 5i card disassembly method: SAS 5i position is in front of the server display board behind, the left front section of the server. 1, open the cover of the case,
2, find the position of SAS 5i card,
3, remove the line on the right,
4, first lift the blue plastic handle on the left, then drag it out to the right. 5. Wrap it in newspaper, put it in a cardboard box, and take it to the computer repair shop.
SAS 5i card is easy to install, no more details.

Reproduced in: https://blog.51cto.com/kunka/1891241