Tag Archives: The operating system

Failed to install realtek HD audio driver Code:0xE0000247

Realtek HD Audio Driver Driver failed to install Error Code:0xE0000247
The problem
After win10 reinstalled, found that the system has no sound, thought it was a driver problem, installed a moving wizard, installed several versions of the sound card drive, egg is not used, but also let me repair this repair that, no egg, has been prompted

why
A little wit, little knowledge
To solve
My motherboard belongs to Asus, so I can find the server support directly on the asus motherboard’s official website:

Search models:

Select the operating system and download the driver:

Error 13 when grub starts: solving the problem of invalid or unsupported executable

I’m using BT3 these days, and as for the USE of IT, we all know that I used GRUb4DOS as my desktop computer to launch recently. In recent days, I want to use my laptop to run BT3, but according to the general setting, GRUB shows Error 13: Invalid or unsupported Invalid on startup.
Looking around, it’s almost certain that the vmlinuz and BT3 cores don’t match, but it’s not clear why the same Settings worked on desktop computers.
The solution is as follows
After recompiling the kernel, restarting the system resulted in a GRUB boot error
Grub Error 13: Invalid or unsupported Invalid format
Error clause xp and FC co-existed when kernel/vmlinuzz-2.6.15 ro root= /dev/volgroup00 /LogVol00 RHGB quiet
installation. Restart the system again, enter xp, and search for the solution to Error 13.
use the rescue disk to enter the fc, check the Settings in /etc/grub.conf file, and check the filename in the Settings. It matches the file on your hard drive.
USES Google again to view the explanation of the vmlinuz file. On linuxidc.com, see
. Vmlinuz is the executable Linux kernel. It is located at /boot/vmlinuz and has two ways to build it. First, the kernel is created by “make zImage” when compiling, and then by:
“Cp/usr/SRC/Linux – 2.4/arch/i386/Linux/boot/zImage/boot/called”. ZImage is suitable for small kernels and exists for backward compatibility. The second is the kernel compile time through the command make bzImage created, then through: “cp/usr/SRC/Linux – 2.4/arch/i386/Linux/boot/bzImage/boot/called”.
Because vmlinuz is before compiling the kernel, the original system does not match the system after compiling the kernel, so it cannot be started
. Restart to enter grub, press e to modify, change vmlinuz-version to bzImage, press b to start Linux
to enter Linux. Go to/boot/ and delete the old vmlinuz, then rename the bzImage to vmlinuz-version
and everything will work fine.

appendix: Conf generated by anaconda
#
# Note that you do not have to rerun grub after making changes to this file
# NOTICE: you have a /boot partition. This means that
# all kernel and initrd paths are relative to /boot/, Eg.
# root (hd0, 8)
# kernel/called – version ro root =/dev/VolGroup00 LogVol00
# initrd /initrd-version. Img
#boot=/dev/sda
default=1
timeout=5
splashimage=(hd0,8)/grub/splash. Xpg.gz
hiddenmenu
title Fedora Core (2.6.15_FC5)
root (hd0,8)
kernel/vmlinuuz-2.6.15 ro root= /dev/volgroup00 /LogVol00 RHGB quiet
initrd /initrd-2.6.15. Img
title Other
rootnoverify (hd0,0)
chainloader +1

An error occurred while Windows was synchronizing with *.*.*.*

Problem description: An error occurred while Windows was synchronizing with time.windows.com
Or An error occurred while Windows was Synchronizing with 10.80.2.80 (internal time server)

Solutions:

    Most of the time you get the error is due to the time server being down, so try again later.
    Most of the time this error is due to the time server service being down, so try again later. Try another Server. (time.nist.gov) Try another time Server. (time.net.gov) Your firewall might be blocking W32Time, disable Firewall, update time and enable again. Close the firewall and resynchronize the time. The following steps will stop and start the time update application. Follow these steps to stop and start the time update program. Start > Run cmd.exe
    net stop w32time
    w32tm.exe /unregister
    w32tm.exe /register
    net start w32time

The original link: http://madman.blog.51cto.com/62132/418537

Reproduced in: https://blog.51cto.com/hunkz/1704211

Windows_ Win7 broadband connection prompt remote access connection manager error

Windows_Win7 broadband Connection prompts Remote Access Connection Manager error

phenomenon: prompts Remote Access Connection Manager error

error: prompts Remote Access Connection Manager error

error 1068: dependent service or group cannot start
error 87: parameter error

fault resolution:

Remote Access Connection Manager service startup depends on two services
and another service to start most of the time:
(1) Telephony service
(2) SSTPS(secure socket protocol service)
(3) Windows Event Log service
set the above three services to “auto” start and start.

2, find the folder path C:\ Windows \system32
in the folder to find the logfile and wbem these two folders,
right click — the administrator to obtain the ownership,
after the restart of the computer.

Reproduced in: https://www.cnblogs.com/jason-wrj/p/10289461.html

SQL server error 15404 solution

The job runs with “domain\ User” and the following error is encountered:
 

JOB RUN: 'Product_JobTest' was run on 2016/10/27 at 4:30:00
DURATION: 0 hours, 0 minutes, 0 seconds
STATUS: Failed
MESSAGES: The job failed. Unable to determine if the owner (domain\user) of job Product_JobTest has server access (reason: Could not obtain information about Windows NT group/user 'domain\user', error code 0x5. [SQLSTATE 42000] (Error 15404)).

 
Read the following reference articles:
http://www.cnblogs.com/kerrycode/p/3339558.html
http://www.cnblogs.com/kerrycode/p/5551994.html
http://consulting.risualblogs.com/blog/2013/03/01/could-not-obtain-information-about-windows-nt-groupuser-domainuser-error-code-0x5-sqlstate-42000-error-15404-connisloginsysadmin/
 
We started to try to modify the owner of the job as SA, and encountered two problems:
1. For the report subscription job generated by the report service, the subscription scheduling time of 2008R2 failed to be modified, and this problem was not encountered in 2014.
2. For the cross-server access job deployed by the business, it will be verified with the startup account of SQL Server Agent service, and the access permission of LINKEDSERVER needs to be configured.

Solutions:
On the domain controlled Server, add the startup account of SQL Server service to “BUILTIN\Windows Authorization Access Group”, and then let the job run with “Domain \ User” as the owner, and no error will be reported.

MS SQL Could not obtain information about Windows NT group/user ‘domain\login’, error code 0x5. [SQ…

An interesting error occurred recently: some jobs on a database server overseas occasionally reported errors, with the following message:
————————————————————————————————————————————————-
Date 2013/9/15 12:00:00
Log Job History (JOB_SYNCHRONIZING_ESCM_DATA_EAV)
Step ID 0
Server EGVNT02
The job name JOB_SYNCHRONIZING_ESCM_DATA_EAV
Step Name (Job Outcome)
Duration 00:04:34
SQL severity 0
SQL message ID 0
Operators who have been notified by E-mail
An operator who has sent a notification over the network
Operators who have been notified by paging
Retry 0
The message
The job failed. Unable to determine if The owner (domain\login) of job JOB_SYNCHRONIZING_ESCM_DATA_EAV has Server Access (Reason: Could not obtain information about Windows NT group/user ‘domain\login’, error code 0x5. [SQLSTATE 42000] (Error 15404)).
————————————————————————————————————————————————-
 
The database version, Microsoft SQL Server 2008 R2 (RTM) -10.50.1600.1 (X64), was created using domain\ Login, which has the sysadmin Server role but belongs to Domain A and is not A member of the Administator group within the system. The login account for the database-related services is as follows:

Search the information from the Internet as follows:
This message is thrown if the SQL Server service uses an account that does not have sufficient administrative credentials on the Windows domain. In this situation, the xp_logininfo system stored procedure is run by using the security context of the SQL Server service. Because the account does not have sufficient administrative credentials to enumerate the properties of the user in the domain, the xp_logininfo system stored procedure fails, and you receive the 8198 error. To resolve this problem, change the startup account of the SQL Server service to a Windows domain account.
We need to either run the SQL service under domain account or use SQL authentication
 
This error message is thrown if the account used by the SQL Server service does not have sufficient administrative credentials. The Windows domain. In this case, the Xp_loginInfo system stored procedure is run in the security context of the SQL Server service. Because the account does not have enough security credentials to enumerate the user’s attributes in the domain, the Xp_loginInfo system stored procedure fails and you receive an 8198 error. To resolve this issue, change the startup account of the SQL Server service to the Windows Domain account.
We need to run the SQL service with the domain account or with SQL authentication.
In fact, it is also very convenient to solve this problem by changing the owner of the job to SA or the account with the role of Sysadmin in the local area. But I’m still confused about the nature of the problem. Why is it that it works most of the time, and occasionally this error occurs?I never understood that.
 
Resources:

Unable to determine if the owner of job has server access


http://www.sqlserver-wiki.com/2012/11/could-not-obtain-information-about.html
 

Solve the problem of ATA bus error after centos7 restart

Yesterday, I installed CentOS7 on my computer, and I also dropped the Win7 system. Since then, Only Centos is installed on my computer, which gives me a feeling of abandonment.
A HALT command tried to shut down the system, but found that the screen wasn’t black, that the machine wasn’t working, and that the power light was still on. So it did its best to hold down the power button and force it off.
When I came back the next night and started the machine, it was abnormal. After starting the machine, there was always an ATA Bus error. Please see the last picture for details.
How to do, Lao Tze did sth. for two or three hours, reinstalled three times the system is the same result! No way I’m white.
Finally search, omnipotent netizens said that the hard disk fault, but my hard disk is absolutely forced not to be broken… In the end,
I tried to solve my problem with one of my better tools, the CMOS discharge!
Think back, the last time I did this was ten years ago, and alas, how time flies… Beside the point.
Yes, open the case, take out the piece of electronics on the motherboard and put it in again. Restart it.
 
It’s a bloody lesson to shut down the halt command.
No, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no. Finally, I have an error report.

451 4.7.0 temporary server error. Please try again later. Prx5

4.7.0 Temporary Server Error. Please try again later. PRX5 solves the instance
It’s sunny and beautiful this morning! Suddenly, I received a call from a customer, saying that all outlook POP3 of their Company’s Exchange 2013 could not be used normally. The user and password verification box popped up, and it was of no use to enter the password repeatedly or confirm directly.
After communication, I was informed that there was a similar fault before, that was when the service of POP stopped and started, and no modification was made recently. After learning the situation, I logged in to the server remotely and checked that the Exchange service was started normally without any problems.
So I quickly configured a POP mode on my computer, and I got an error when Verifying the user name and password. It didn’t matter if I entered the password repeatedly or confirmed it directly, as described by the customer, as shown in the figure below

What do you do next?Restart the server?This is the next best thing. Maybe a restart can solve your problem temporarily, but the reason is not found, and the problem recurs later. How to deal with it?
451 4.7.0 Temporary Server Error. Please try again later. PRX5
The Telnet test format is as follows:
 
telnet mail.xxx.com 25
Ehlo XXX or HELo, [ESMTP ehlo XXX, SMTP HELo, I’ll fill ehlo XXX, XXX whatever]
Mail from:[email protected][administrator address]
RCPT to:[email protected][recipient address]
Data [Start writing email]
From :XXX[sender address]
To :XXX[Recipient address]
Subject: CEShi pop3 Send and Receive [subject]
Ceshi pop3 send and receive[Note: The body of the email should be blank, otherwise it will be automatically determined as the subject. If you want to send Chinese, you need to download Telnet client separately, see attachment]
.[End of message identifier]
Normally it will prompt you that the message has been queued for sending
Quit [After sending the email]
 

Step 1. Google the cause of the error and find the solution to the problem.
Reference 1.
https://social.technet.microsoft.com/Forums/exchange/en-US/fc26dac5-d4e2-49da-903d-361ea8b85388/451-470-temporary-server-error-please-try-again-later-prx5
I talked to a MS support rep today and they confirmed the same problem, except to resolve it we had to add the local server’s IP to our hosts file:
192.168.1.5 server
192.168.1.5 server. The domain. The local
Restart “Microsoft Frontend Transport” and “Microsoft Exchange Transport” services
The support agent stated that he’s seen this in a few cases now. All of which are when the Exchange server front and back-ends reside on the same box. Sounds like an Exchange bug to me.
Reference 2,
http://blog.5dmail.net/user1/1/2014414174021.html
 

Exchange Server 2013 cannot receive emails sent from outside. Remote Host said: 451 4.7.0 Temporary Server Error. Please try again later. PRX2
 
[Reason analysis]
The Exchange Server 2013 in question was installed with multiple roles. Including the mailbox and client access roles of DOMAIN control and Exchange 2013, and because the client server is hosted in the computer room, it is equipped with two network CARDS, which are configured with an Intranet IP and a public network IP respectively, the fault is mainly caused by the two network CARDS using different DNS.
 
Step 2: Modify the local C:\Windows\System32\drivers\etc\ hosts file, add and save the local records of Exchange 2013 server.

Step 3. Check the Exchange server and THE AD domain server, and check that the DNS is pointing to the inside and there is no record pointing to the outside.
Step 4. Restart the “Microsoft Frontend Transport” and the “Microsoft Exchange Transport” services


Step 5: If you restart the “Microsoft Frontend Transport”, the Transport service has stopped and cannot get up, restart the server?No, we open the task manager, find Msexchangetransport.exe finish the task and restart the Transport service.

Step 6. After the processing, we tested a Telnet test. The specific method referred to the description in the previous part of the article, and the email was successfully sent.

Step 7. When opening Outlook, the test has been successfully tested, the receiving and sending is normal, and there is no password box prompt, and the fault is solved. Thank you for your patience to watch, thank you!

 

Reproduced in: https://blog.51cto.com/yuntcloud/1584670

ArcGIS desktop experience. Similar to: error 000732 output Geodatabase

Until the release of ArcGIS Desktop 10 SP1
 
1: in the desktop ArcGIS9, inside the Geodatabase (PGDB, FGDB, ArcSDE GDB) create a Table (Table), if the Table name begin with GDB (GDB, gdb1, GDBSDF, gdb_3d, etc.) after creating all could not see the form, and in fact is the existence of this Table, if you create a Table with the same Table will be prompted to exist, can use PGDB open Access to view, create a class there is no problem. There is no problem with ArcGIS10.
Problem analysis: currently, just a guess, because ArcGIS9 GDB Schema are GDB_ table in the beginning, the Schema are invisible to users in ArcCatalog, speculation is likely the GDB to block out the beginning of the table, don’t show, but while streamlining the GDB with ArcGIS10 Schema, but there are still four tables, starting with the GDB ArcGIS10 create tables can be seen, a bit surprised, may ArcGIS10 write these four table table name directly in the dead into the program.
2: when using ArcGIS desktop import export data, because the default using ArcGIS to create objects and other elements of the system will create a ObjectID fields, is a unique identifier, some users will use this ObjectID, may record the corresponding ObjectID to correspond to the specified elements, but in the process of data import and export, especially the import, the user will be very depressed these ObjectID rearrangement, so users will not be able to come here to use the ObjectID, how should do?
The ObjectID is rearranged by the Import/Export tool. It is suggested that users use Copy/Paste directly to the data set or element class object. In this way, ObjectID is not rearranged.
3: In the process of data Import using ArcGIS desktop, take Import as an example, “Output Location” in the Import box prompts a small Red Cross, such path does not exist or error-000732 Error occurs?
Solution: the relative path “Database Connections/Connection to lish. Sde” is modified to the absolute path “C:/Users/gis/AppData/Roaming/ESRI Desktop10.0 ArcCatalog/Connection to lish. Sde”, because the problem some machines have similar problems, some machines have no, the reason is still unknown.
4: When SDE creates or imports data containing the field name “AREA”, the field name is automatically prefixed.
Question: This problem exists in ArcGIS9 software, but not in ArcGIS10, for unknown reasons!
5: When creating a LoadRaster dataset, if the whole Raster was loaded and the InputRaster prompted the Red Cross, the Raster object had to be double-clicked and opened into three bands to be loaded. How could the whole Raster object be loaded without being loaded in the form of bands?
Problem analysis: The default Rand Number selected by the user when creating a RasterDataset was “1”. Setting the Rand Number to “3” would solve the problem.
6: Users are using joins to mount tables (element classes versus normal tables), but sometimes a library cannot be mounted on a non-Windows operating system. What can be done?
Problem analysis: Because the Join is using Ole mechanism for articulated, but the Windows operating system default Ole drive, but not the Windows operating system, so the Windows operating system does not support Ole, which does not support the use of the Join, so users can completely change the way in which different using sde commands to complete (sdetable – o create_view), effect is the same, and taking advantage of sde command to create a view can be saved, read-only, This view can be treated as a read-only element class.
sdetable command reference: http://wenku.baidu.com/view/16c6362acfc789eb172dc8c2.html
7: Use ArcCatalog to export ArcSDE data to PGDB and import it in. Some field ranges change.
Problem analysis: Import field for text, for example, because PGDB is usually Access, the text field’s biggest support for Access to 255, more than the value into the remark field, so if a user ArcSDE text field length is 1000, then imported into the PGDB inside because of greater than 255 into the remark field, then pour into ArcSDE, note field does not record length, directly convert note length to CLOB (in Chinese version is more than 2000 of Oracle database with CLOB storage), so, If the user does not want to encounter this phenomenon during the data import and export, please replace the exported PGDB with FGDB.

8: when using ArcMap or ArcGIS Engine for simple operations such as map enlargement, the following phenomenon occurs: the map is blank, “gsrvr.exe” Error or “Network IO Error” Error is prompted?
Problem analysis: First, check whether the user’s database matches the version of your ArcSDE. This error is typical ArcGIS9.3/9.3.1 and Oracle10.2.0.1 (note the small version number of the database). It is suggested that the database should be Oracle10.2.0.3.
9: In the editing process of using ArcCatalog, when saving data, prompt: “Create: An unexpected failure in Dimension”, OrA-20092: Maximum number of Grids per feature(8000) excplug.Ora-06512: In “SDE_ST_DOMAIN_METHODS” line 1487 and so on.
Problem analysis: ArcGIS defaults that an object cannot exceed 8000 grids, which is a hard and fast rule, so it means that the grid setting of the layer edited by the user is too small or an object edited by the user is too large. Either the user deletes the index, rebuilds the index, or the user edits the grid value and replaces it with a larger grid value.
10: Null character missing at the end of the ArcMap import datagram ORA-01480 STR bound value.
Problem solving: if the user has this problem, the user’s machine configuration should be
operating system: Windows Server 2003/2008 Enterprise x64 SP2
Oracle version 10.2.0.4.0-64bit
ArcSDE version: ArcSDE 9.3.1 for oracle10g64
DeskTop version: 9.3.1
vector storage mode: ST_Geometry
this has no way, if the user’s configuration completely meets the above configuration, congratulations, you are so lucky, this is all encountered by you, as of press ArcGIS9.3.1 also did not solve the problem.
The user could either use a direct connection to derive the data, or use BLOB storage instead of ST_Geometry storage, and presumably more people would choose the first option.
11: ArcMap USES Identify figure to find both length and area are 0?
The user must be using SDO_Geometry geometry to store geometry data. The structure is not at all like the ST_Geometry structure where length and area can be recorded, so this is normal.

Solution to prompt run time error “438” when a VB program is opened

RT, the error is as follows:

Run-time error “438”
Object doesn’t support this property or method

The solution is as follows:
Win + R brings up the run box, type Services.MSC to open the service and stop the following service:

Windows Management Instrumentation

Open the following path and empty the folder:

C:\Windows\System32\wbem\Repository

Be careful not to make the mistake of emptying WBEM, which can have serious consequences unless the files are retrieved from the original system.
Go back to the service, start what you just stopped, open the error reporting program again, and run normally!
The same error solution may not be universal and is for reference only.